Controls

 
  • Allen-Bradley PLC is the standard control system

  • Optional computer-based controls for operator interface, data acquisition and archiving

  • Sequential control with digital analog inputs and outputs

  • Digital puller speed selection synchronized through the PLC

  • Closed-loop puller cylinder stroke

  • Puller speed is insensitive to process pull load changes

  • Touch-sensitive monochrome display screens

  • Control sequences provided for "start up"; run modes include puller cycles of "Jog", "Intermittent Single Clamp", "Continuous Dual Clamp" and "Tandem Dual Clamp"

  • All temperatures are established from the touch screen and controlled by PLC PID logic loops

  • Temperature control zones sufficient for machine die loading

  • Solid state relays to control temperature zone power with power flow indication

  • Automatic digital encoder inputs, mechanical limit switches, or two-wire sensor outputs control cut-off cycles

  • Controls located in NEMA 12 enclosures

Touch screen operator interface

PLC control panel

Standard heat control panel

 

 

 

     
     